A sensor that measures temperature is called a temperature sensor.
Temperature sensors can be roughly divided into two types: contact sensors, which measure by contacting the object to be measured, and non-contact sensors, which measure without contacting the object to be measured.
Here we introduce thermocouples and resistance thermometer, which are widely used to measure temperature, especially in testing and research sites, and in production sites such as factories.
For a detailed explanation of thermocouples and resistance thermometer, please see What is a temperature sensor?
Sheathed Thermocouple
Solid Pack Thermocouples General purpose thermocouple |
Sheaths resistance thermometer
General Purpose resistance thermometer |
Explosion proof sensor Thermocouple Resistance thermometer |
Surface Sensors Thermocouple Resistance thermometer |
Food Sensors Thermocouple |
Silo Cable Thermocouple Resistance thermometer |
Cryogenic Sensors Resistance thermometer |
Other sensors for multiple purposes Thermocouple Resistance thermometer |
Models | SC |
Temperature range | -200~1050℃ |
Wire and element | K, E, J, T, N, (R) |
Protective tube outer diameter | φ0.1~φ8.0mm |
Standard Sensor Length | 300, 500, 750, 1000, 1500, 2000mm |
Models | NC |
Temperature range | -40~1200℃ |
Wire and element | K |
Protective tube outer diameter | φ10mm, φ15mm, φ22mm |
Standard Sensor Length | 300, 500, 750, 1000, 1500, 2000mm |
Solid pack thermocouples are temperature sensors with large diameter protective tubes of φ10 to 22 mm that combine the sensitivity of sheathed thermocouples with robust required for industrial use.
Models | NR |
Temperature range | -200~500℃ |
Wire and element | Pt100, JPt100 3-wire system |
Protective tube outer diameter | φ3.2, φ4.8, φ6.4, φ8.0mm |
Standard Sensor Length | 300, 500, 750, 1000, 1500, 2000mm |
Models | SCN |
Temperature range | -40~900℃ |
Wire and element | K |
Protective tube outer diameter | φ1.6, 4.8mm |
Standard Sensor Length | SCN05 - 3 types: 100mm, 150mm, and 300mm SCN06 - 2 types: 300mm and 500mm SCN07 - 100mm and 300mm |
This sensor is a general-purpose sheathed thermocouple.
Models | RN |
Temperature range | -200 to 300°C (However, the conductor connection part is -20 to 100°C) |
Wire and element | Pt100, JPt100 3-wire system |
Protective tube outer diameter | φ4.8mm |
Standard Sensor Length | RN05 - 3 types: 100mm, 150mm, and 300mm RN06 - 300mm and 500mm |
Models | |
Normal temperature | 200℃※ |
Wire and element | K,T,J,E |
Kinds | General use, high temperature use, fluororesin |
Models | SC, NC |
Temperature range | -200~1200℃ |
Wire and element | Pt100 |
Protective tube outer diameter | φ1.0~22mm |
explosion proof structure types | Intrinsically safe explosion proof proof structure (IA) |
Models | SC(ExdII CT5) |
Temperature range | -200~1200℃ |
Wire and element | K,E,T,N |
Protective tube outer diameter | 3.2, 4.8, 6.4, 8.0 (φmm) |
Protective Tube Material | SUS316 |
Models | RU, NRD |
Temperature range | -200 to 650°C (JPt100 is 500°C) |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ3.0~φ16mm |
Protective Materials | SUS304, SUS316, SUS310S, SUS347 |
Models | NR800-6, NR800-7 |
Temperature range | 4K to 375K (NR800-6), 15K to 375K (NR800-7) |
Wire and element | Pt100 |
Protective tube | φ2x30mm |
explosion proof structure types | Intrinsically safe explosion proof proof structure (IA) |
Models | NR |
Temperature range | -200~500℃ |
Wire and element | Pt100 |
Protective tube outer diameter | φ2.0~8.0mm |
explosion proof structure types | Intrinsically safe explosion proof proof structure (IA) |
Models | NR(ExdII CT5) |
Temperature range | -200~500℃ |
Wire and element | Pt100, JPt100, Vibration-resistant Pt100 |
Protective tube outer diameter | 3.2, 4.8, 6.4, 8.0 (φmm) (Vibration-resistant Pt100 is not compatible with φ3.2) |
Protective Tube Material | SUS316 |
Models | CU, SCD |
Temperature range | -200~1200℃ |
Wire and element | R,K,E,J,T |
Protective tube outer diameter | φ1.5~22mm |
Protective Materials | SUS304, SUS316, SUS310S, SUS347, NCF600, Kanthal |
Models | R060 |
Temperature range | -10~500℃ |
Wire and element | Pt100, JPt100 |
Models | C060 |
Temperature range | -40 to 300°C (insulation paper can withstand temperatures up to 250°C.) |
Wire and element | K, T |
Connecting wire | φ0.32mm K, T thermocouple wire |
Models | C400-01 |
Temperature range | 0~100℃ |
Wire and element | K (ribbon thermocouple) |
responsiveness | Room temperature → 100℃ boiling steam on iron plate for about 2 seconds |
Models | R400 |
Temperature range | 0~60℃ |
Wire and element | Pt100, JPt100 |
Connecting wire | Vinyl-coated copper conductor 2m included |
responsiveness | Room temperature → 100℃ boiling steam on hot plate, approx. 97 seconds |
Models | C401 |
Temperature range | 0~150℃ |
Wire and element | K,T |
responsiveness | Room temperature → 100℃ nickel-plated aluminum plate for about 10 seconds |
Models | R401 |
Temperature range | 0~150℃ |
Wire and element | Pt100 |
Connecting wire | Silicone-coated copper conductor 2m included |
responsiveness | Room temperature → 100℃ nickel-plated aluminum plate for about 25 seconds |
Models | C015 |
Temperature range | room temperature to 250℃ (for general use), room temperature to 500℃ (for high temperature use) |
Wire and element | K |
Measured distance | 1 to 2 mm constant |
Models | R101, R102, R103 |
Temperature range | -20~60℃ |
Wire and element | Pt100, JPt100 |
Number of measurement points | R101 max 11 points, R102 max 5 points, R103 max 1 or 2 points |
Models | C201 |
Temperature range | -20~200℃ |
Wire and element | K φ0.32mm FEP coating |
Number of measurement points | Max 6 points |
Models | SCHS1-7 |
Temperature range | -60~650℃ |
Wire and element | K,T |
Protective tube outer diameter | φ1.0, φ1.6mm |
Standard Sensor Length | 100, 200mm |
Models | C030 |
Temperature range | 0~200℃ |
Wire and element | T |
Protection tube dimensions | φ2x100mm or φ3.2x100mm |
This sensor is suitable for measuring the ambient temperature and actual temperature of food during sterilization in order to computation the F value, which indicates the effectiveness of heat sterilization of canned foods, retort foods, etc.
Models | R800-6, R800-7 |
Temperature range | 4K to 375K (R800-6), 15K to 375K (R800-7) |
Wire and element | Pt100 |
Protective tube | φ2x20mm |
Lead | 4-wire polyester-coated copper wire φ0.2×L1000mm |
Models | C025 |
Temperature range | 0~300℃ |
Wire and element | K, J (2 pairs also possible) |
Protection tube dimensions | C025-12: φ22×270mm+φ9×30mm C025-11: φ16×270mm+φ9×30mm |
Models | C008 |
Temperature range | 0~400℃ (K,J,E), 0 to 200°C (T) |
Wire and element | K,E,J,T |
Protective tube outer diameter | φ4.8, φ6.0mm |
Models | R985-3W |
Temperature range | -50~150℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ8.0mm |
Protection Manager | 60mm |
Models | R907-3 |
Temperature range | -200~180℃ |
Wire and element | Pt100, JPt100 |
Connecting wire | Fluorine resin coated conductor 1m included |
Models | R906-3 |
Temperature range | -50~200℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ3.2mm |
Protection Manager | 100mm |
Models | R905-3 |
Temperature range | -50~200℃ |
Wire and element | Pt100, JPt100 |
Resin mold outer diameter | φ4.3mm |
Protection Manager | 60mm |
Models | R903 |
Temperature range | -50~150℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ8.0mm |
Protection Manager | 50mm |
Models | R900, R902 |
Temperature range | 0~150℃ |
Wire and element | K,T |
Protective tube outer diameter | φ6.0, φ8.0, φ10.0mm |
Standard Sensor Length | 100mm |
Models | R610, R620 |
Temperature range | -50~150℃ |
Wire and element | Pt100, JPt100 |
Connecting wire | Teflon-coated copper conductor |
Models | R420-32F |
Temperature range | 0~60℃ |
Wire and element | Pt100 |
Connecting wire | Vinyl-coated copper conductor 2m included |
responsiveness | Room temperature → 60℃ Aluminum pipe (outer diameter φ60, wall thickness 10mm) Surface: approx. 6 seconds |
Models | R050 |
Temperature range | -50~150℃ |
Wire and element | Pt100, JPt100 (some) |
Protective tube outer diameter | Two types: φ9×50mm+φ12×100mm, φ9×50mm+φ12×150mm |
Protective Tube Material | SUS304 |
Models | R040 |
Temperature range | -50~100℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ2.0mm |
Standard Sensor Length | 100,200mm |
Models | R033 |
Temperature range | -10 to 60°C (for R033-3V) |
Wire and element | Pt100 |
Case Material | Aluminum |
Installation Method | Wall Mounting |
Models | R005 |
Temperature range | -50~350℃ |
Wire and element | Pt100 |
Protective tube outer diameter | φ6mm (except for the fast-acting type, which is φ3.2mm) |
Standard Sensor Length | 100,200,300,500mm |
Models | R003 |
Temperature range | -50~200℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ1.0, φ1.6mm |
Standard Sensor Length | 100, 200mm |
Models | R000, R011, R030, R031 |
Temperature range | -50 to 150°C (for R000) |
Wire and element | Pt100, JPt100 (some) |
Protective tube outer diameter | φ2.5mm, φ6mm, φ12mm |
Installation Method | Wall Mounting |
Models | NRZR |
Temperature range | -200~500℃ |
Wire and element | Pt100, JPt100 |
Protective tube outer diameter | φ3.2, 4.8, 6.4, 8.0mm |
Protective Tube Material | SUS316 |
Models | NRHS1 |
Temperature range | -70~500℃ |
Wire and element | Thin-film resistance thermometer Pt100 |
Protective tube outer diameter | φ4.8, φ6.4, φ8.0mm |
Standard Sensor Length | 300, 500, 750, 1000, 1500, 2000mm |
Models | |
Temperature range | It depends on resistance. |
Kinds | For R, S, K, N, E, J, T, C, B |
Models | |
Temperature range | It depends on resistance. |
Kinds | 3-core, 4-core, 6-core, 8-core |
Finished size | Approx. 2.2 to 10 mm |
If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.
You must be a login to download.