Intrinsically safe explosion proof resistance thermometer NR (Japan Standards)

Sheathed and solid-pack temperature sensors, when combined with a Zener barrier or insulation barrier, have passed the intrinsically safe explosion proof equipment inspection by the Technology Association of Industrial Safety (a type inspection agency designate the Ministry of Health, Labor and Welfare).

■ Zener Barrier
· DIN rail mounting and intrinsic safety ground (earthing) are possible at the same time.
- Three-terminal connection is possible, and one barrier can be used with one sensor.

■ insulation Barrier
No installation work required. Excellent noise immunity due to no installation.
Compatible with 2-wire, 3-wire, and 4-wire resistance thermometer (switchable).

configuration of a sensor, a Zener barrier, and an insulation barrier

Specifications

Intrinsically safe explosion proof resistance thermometer

Sensors Models NR Series
Wire and element Pt100
Protection tube dimensions Outer diameter φ2.0 to 8.0 mm
Length: 50 to 5,000 mm
explosion proof specifications models name IS21
explosion proof structure types Intrinsically safe explosion proof proof structure (IA)
Explosion class and ignition level of the target gas or vapor IICT4
Permissible voltage of intrinsically safe circuit 6.6V
Permissible current of intrinsically safe circuit 900mA
Type inspection approval number No. TC19308

Zener barrier (for resistance thermometer)

Combination Barrier Models MTL7756ac
Non-intrinsically safe circuit allowable voltage 250V AC 50/60Hz
250V DC
Voltage and current used 0.7V AC 250mA
terminal resistance 19Ω (max)
Type inspection approval number No. TC16437

insulation barrier (for resistance thermometer)

Combination Barrier Models MTL5582
Non-intrinsically safe circuit allowable voltage 250V AC 50/60Hz
250V DC
Output Signal resistance thermometer (RTD) output
Power supply 20-35VDC
Maximum current consumption 33mA (at 24V DC)
Type inspection approval number No. TC20279
*Please refer to the catalog for other specifications.

Download Documents & Softwares

Catalog

Specification Sheet (PS Sheet)

  • Intrinsically safe explosion proof insulation barrier (for thermocouples/ resistance thermometer)
    ファイルサイズ1MB
    Document No.
    PE-70-2
  • Intrinsically safe explosion proof Zener barrier (for thermocouples/ resistance thermometer)
    ファイルサイズ1MB
    Document No.
    PE-58-3
  • Temperature Sensors (Japan Only)
    ファイルサイズ1MB
    Document No.
    PE-02-9
  • General Industrial Temperature Sensors
    ファイルサイズ1MB
    Document No.
    PE-03-13
  • Sheathed resistance thermometer
    ファイルサイズ1MB
    Document No.
    PE-31-13
  • English) NR Sheathed resistance thermometer
    ファイルサイズ1MB
    Document No.
    PSE-393

CAD Data

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."

Instruction Manual

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."

Softwares

Application Examples

Related Info

Movie

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.