Explosion explosion proof thermocouple CU,SCD (Japan Standards)

explosion proof thermocouples CU, SCD explosion proof thermocouples are temperature sensors used in places where flammable gases or vapors of flammable liquids are present and there is a risk of ignition and explosion.
structure consists of a pressure-explosion proof terminal box that can withstand an internal pressure of 1 MPa gauge pressure, terminal board made of diaryl phthalate resin with good insulation, a protective tube, mounting bracket, wires or elements, and an insulation tube. Depending on the type of mounting bracket, straight, flange, or nipple types are available.

Dedicated terminal box available, hydrogen explosion proof proof

  • The sensor can be used in hazardous locations with explosion and ignition ratings of d2G4.
  • All threaded parts of the lid and body of the terminal box that can be opened from the outside, threaded parts of the protection tube and terminal box body, and threaded parts for attaching metal conduit pipes are based on factory electrical equipment explosion proof pointer (gas, steam explosion proof).
  • terminal board is made of diaryl phthalate resin for insulation, with the minimum creepage distance between terminal and between terminal box and terminal being 8 mm, and the minimum insulation clearance being 8 mm.
  • The boundary between terminal box and protective tube is a pressure-resistant stud-type pull-in method for the standard type, and a pressure-resistant resin-fixed pull-in method for the sheath type.

Specifications

explosion proof specifications

explosion proof structure Explosion explosion proof structure
Explosion and ignition ratings d2G4
Hazardous area of use 1st and 2nd class
Lead Wiring Method Metal conduit is screwed into terminal box
Conduit Screw G1/2
ground Method Using metal conduit as a substitute for ground wire
Construction method Plant electrical equipment based on explosion proof pointer (gas steam explosion proof)

Thermocouple specifications

Wire R., K., E., J., and T.
Tolerance R - JIS Class 2
K, E, J, T - JIS Class 1, Class 2
Measurement temperature R--0 to 800°C
K - -200 to 1200°C
E - -200 to 600°C
J - 0 to 500°C
T - -200 to 250°C
* Varies depending on specifications
Protective tube outer diameter φ1.5~φ22mm
Protective Tube Material SUS304, SUS316, SUS310S, SUS347, NCF600, Kanthal
*Please refer to the catalog for other specifications.

Application Examples

Related Info

Movie

FAQ

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.