Temperature Calibration Equipment and Standard Sensors

Temperature calibration equipment and standard thermometers

What is "correct temperature measurement"?

In order to measure the correct temperature, it is necessary to "calibrate as necessary and ensure traceability" as stipulated by the JIS.In addition, "even if a thermometer with guaranteed traceability is used, errors may occur depending on the measurement conditions," so there are cases where a simple calibration is performed and the measurement is not recognized as correct even if traceability is ensured.

To perform calibration

To perform calibration yourself, you will need to prepare the object to be calibrated (the sensor that needs to be calibrated), a standard thermometer, and the environment in which the calibration will be performed (such as a furnace).
At CHINO, we offer a lineup of standard thermometers, including standard temperature sensors (thermocouples, resistance thermometer) and standard radiation thermometer, as well as various calibration furnaces and fixed-point calibration devices.

Chino is a sensor and calibration equipment manufacturer and an international MRA-compliant JCSS-certified business.

We can provide the support that only a company that manufactures both sensors and calibration equipment and also provides calibration services can provide.
If you find it difficult to calibrate by yourself, we can also calibrate just one sensor. Please feel free to contact us.

Related Documents

Calibration Test & Temperature Calibration Equipment
Field Inspection and Calibration Service Guide

Related Links

Choose a Product

Standard thermometer

Thermocouple Resistance thermometer IR Thermometers
C800
C810
C820
C850
R800
CAB-F201+R900-F25AD
IR-RST

Calibration Sensors/Equipment

Fixed-point calibration Comparison Calibration
Temperature Sensors (Japan Only) KT-H503, KT-H504, KT-H504S
KT-H101, KT-H102, KT-H211, KT-H301
KT-B22, KT-B23
KT-F311, KT-F312, KT-F313
IR Thermometers IR-R0A
IR-R80
IR-R20
IR-R24, IR-R26, IR-R27
IR-R6, IR-R7, IR-R8
Thermal image measurement
Thermography camera
Infrared temperature measuring device
Radiation thermometer
IR-R40, IR-R41

Product Line

Standard thermocouples and standard resistance thermometer

  • Models KT-M
    Base unit
    Number of channel
    6ch, 24ch
    Input unit thermocouple
    (N, B, S, R, K, E, J, T)
    resistance thermometer
    (Pt100, Pt-Co)
    It converts signals from thermocouples or resistance thermometer into high accuracy digital signals and outputs them digitally to a recorder or computer.
  • Models CAB-F201
    Measurement temperature range -200 to 850℃ (JIS, DIN, CvD)
    Accuracy ratings ±0.01℃
    display resolution 0.001℃
    Input Type Pt100 (4-wire)
    This high accuracy digital thermometer for resistance thermometer can measure temperature at 2 or 8 points. The calibration data of the temperature sensor can be memory, enabling accurate temperature measurement.
  • Models C800
    Wire S, R, B thermocouples
    Wire diameter Φ0.5mm
    Wire length 1500mm
    Maximum temperature 1100℃(S・R) / 1554℃(B)
    Standard temperature sensors for thermocouple calibration include S, R and B thermocouples. We can create a temperature-thermoelectromotive force table upon designate.
  • Models C810
    Operating temperature For use with silver point (961.78℃) or copper point (1084.62℃)
    Wire Material Platinum(+) Palladium(-)
    Wire diameter Φ0.5mm
    Wire length 2800mm
    Compared to conventional thermocouples that use precious metal thermocouples (R, S, B) specified by the JIS, stability at high temperatures is significantly improved.
  • Models C820
    Operating temperature 0~1300℃
    Wire Material Platinum(+) Palladium(-)
    Wire diameter Φ0.5mm
    Wire length 1800mm
    Compared to conventional thermocouples that use precious metal thermocouples (R, S, B) specified by the JIS, stability at high temperatures is significantly improved.
  • Models C850
    Operating temperature 0~1000℃
    Wire Material Gold (+) Platinum (-)
    Wire diameter Φ0.5mm
    Wire length 1800mm
    The electromotive force drift when exposed to high temperatures is small, and the uncertainty due to inhomogeneity is also significantly reduced.
  • Models R800
    Measurement range 4K to 962℃
    Winding frame Cruciform Quartz
    This is a standard platinum resistance thermometer development based on the 1990 International Temperature scale (ITS-90) under the guidance of the Agency of Industrial Science and Technology's National Institute of Metrology.

Temperature sensor comparison calibration device

Standard radiation thermometer

  • Models IR-RST
    Measurement method Monochromatic radiation thermometer
    Measurement temperature range 150~3000℃
    Resolution 0.1℃
    This is a monochromatic radiation thermometer used as a standard for comparative calibration radiation thermometer using a comparison blackbody furnace.

Blackbody furnace for fixed-point and comparative calibration

Flat blackbody Furnace

  • Models IR-R40
    Calibration Temperature Range (Ambient temperature +5)℃ to 50℃
    Classification Tabletop type

    The IR-R40 is a flat blackbody furnace that achieves high emissivity in the long-wavelength infrared band and was jointly development with the National Institute of development Industrial Science and Technology (AIST).

  • Models IR-R41
    Calibration Temperature Range -15℃ to 120℃ (ambient temperature 23℃)
    Classification Tabletop type

    The IR-R41 is a flat blackbody furnace that achieves high emissivity in the long-wavelength infrared band and was development jointly with the National Institute of development Industrial Science and Technology (AIST).

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.