The JU series is a small, lightweight, single-phase thyristor regulator with high panel mounting density.
There are two control methods available: a general phase control method and a frequency division control method that performs zero-cross switching, and you can switch between them.
A wide range of option are available, including heater disconnection alarm and current limiting functions.
control Method | Fast acting fuse | Models |
---|---|---|
Phase control /voltage feedback method/frequency division control method | Built-in | JU10010VA000 |
Phase control / current feedback method/frequency division control method | Built-in | JU10010AA000 |
Phase control /power feedback method/frequency division control method | Built-in | JU10010WA000 |
Phase control, no feedback /frequency division control method | Built-in | JU10010NA000 |
Frequency division control method | Built-in | JU10010CA000 |
Phase control /voltage feedback method/frequency division control method | None | JU10010VN000 |
Phase control / current feedback method/frequency division control method | None | JU10010AN000 |
Phase control /power feedback method/frequency division control method | None | JU10010WN000 |
Phase control, no feedback /frequency division control method | None | JU10010NN000 |
Frequency division control method | None | JU10010CN000 |
Number of phases | Single Phase |
---|---|
Rated current | 10, 20, 30, 50, 75, 100, 150, 200, 250, 300, 400, 500A (designate type) |
Rated voltage | 100, 110, 120, 200, 220, 240, 380, 400, 440V AC (designate type) |
Rated Frequency | 50/60Hz (automatic switching) |
Permissible frequency fluctuation | ±2Hz of rated frequency (performance guaranteed range is ±1Hz) |
Operating temperature limit | -10 to 55°C (performance guaranteed range is 0 to 50°C) |
Input Signal | terminal switching between 4 to 20mADC (internal resistance 100Ω), 1 to 5VDC (internal resistance 25kΩ), ON-OFF contact signal, and resistance signal (10kΩ, for manual use) |
Output Range | 0 to 98% of rated voltage |
Minimum load current | 0.5A or more (at 98% output of rated voltage) |
Applied load | resistance load, inductive load (transformer primary side control, phase control only) |
Output control Method | Phase control /frequency division control (switchable depending on the model) |
current Protection | Thyristor gate off (120% or more of the rated current, when the CT is built-in or external) |
Cooling Method | Rated current 150A and below: natural-cooling, 200A and above: equipped with cooling fan |
Other features | Soft start, soft up/down (variable from 1 to 20 seconds) Soft start when recovering from momentary power failure |
External dimensions | H150×W70×D165mm (for 10A, 20A) H352×W60×D190mm (for 30A to 75A) H325×W128×D190mm (for 100A to 250A) H495×W128×D230mm (for 300A to 500A) |
Weight | 10A, 20A type, approx. 2kg, 30A to 75A model: approx. 3kg, 100A, 150A type: approx. 6kg, 200A, 250A type: approx. 7kg, 300A to 500A Approx. 12kg |
The JU series is a small, lightweight, single-phase thyristor regulator with high panel mounting density.
J.U.
We offer a wide range of models to control various heaters in industrial furnaces, machines, equipment, etc.
JZ/JB/JU/JW
If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.
You must be a login to download.