analog scale matches the measurement input, and scale plate can have up to three scale, so it can handle multiple inputs and the measurement value can be read at a glance.
Input type, scale, etc. are adjusted according to your instructions, so no complicated settings are required. Simply turn on the power and you can start giving instructions and recording immediately.
In addition to the many features that enhance ease of use, we also support custom orders, such as adding special functions to suit various devices and applications.
TRAMS can be downloaded from our website.
*An option communication interface is required for recording on a PC.
Models | Number of input points |
---|---|
KL4□06-N0A | 6 points |
Number of measurement points | 6 points |
---|---|
Input Type | DC voltage: ±6.9mV, ±13.8mV, ±27.6mV, ±69.0mV, ±5V DC current: Supported by adding an external shunt resistor (100Ω, 250Ω) Thermocouple...K, E, J, T, R, S, B, N, U, L, W-WRe26, C(WRe5-WRe26), PtRh40-PtRh20, NiMo-Ni, CR-AuFe, PlatinelⅡ, Au/ Pt resistance thermometer …Pt100, old Pt100, JPt100, Pt50, Pt-Co |
Accuracy ratings | ±0.1% of measurement range ±1 digit (DC voltage V input) |
Measurement Interval | Approx. 5 seconds/6 points |
Reference junction compensation accuracy | K, E, J, T, N, Platinel II...±0.5°C or the value equivalent to 20μV of electromotive force Whichever is larger Other than the above: ±1.0℃ or the electromotive force equivalent to 40μV Whichever is larger Ambient temperature: 23°C ±10°C |
Recording method | Wire dot method 6 color ribbon |
Recording Color | analog recording: Red, black, blue, green, brown, purple |
chart paper | Foldable, total width 114mm, total length 10m, effective recording width 180mm |
Paper feed speed | selectable from 1 to 1500mm/h in 1mm intervals (However, it can be set to 12.5mm) |
Fixed time recording | analog recording with digital recording of date, time, channel number, data, and unit. interval (hour, minute) selectable |
Data Print | analog recording can be interrupted on demand to digitally record time and measured value |
Alarm Printing | When an alarm occurs: time of occurrence, channel number, alarm type, alarm level When alarm reset: reset time, channel number, alarm type, alarm level |
Rated power supply voltage | 100-240V AC, 50/60Hz |
scale plate | Maximum 3 scale |
Power consumption | 最大38VA |
Operating temperature limit | 0~50℃ |
Operating humidity range | 20 to 80% RH |
Weight | 約3.0kg |
communication interface (option) | Three types: RS-232C, RS-422A, and RS-485 |
If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.
You must be a login to download.