Fuel Cell Testing System (Japan Only)

Fuel Cell/Water Electrolysis Evaluation Equipment Selection Guide
Carbon Neutral: Efforts towards a carbon-free society

asset-flow3

Needs for hydrogen technology and examples of Chino's evaluation equipment delivery

Hydrogen technology needs (keywords)
Examples of our evaluation equipment delivery
make
Polymer water electrolysis
Hydrogen is produced by electrolyzing water in an electrolysis cell that uses a solid polymer membrane. While alkaline water electrolysis uses an aqueous solution of potassium hydroxide, this method uses pure water as the raw material. It utilizes the know-how of PEFC (solid polymer electrolyte fuel cell) evaluation test equipment.
・PEM type water electrolysis evaluation test equipment
High Temperature water vapor Electrolysis (SOEC)
Using a high-temperature electrolysis cell that uses oxide-based solid electrolytes (Solid Oxide Electrolysis), such as conductive ceramics, hydrogen is produced by electrolyzing high-temperature water vapor at approximately 700°C. Heat can be used for electrolysis.
・SOEC evaluation device
Alkaline water electrolysis
Hydrogen is produced by electrolyzing an aqueous solution of potassium hydroxide. Hydrogen is produced at the cathode, and oxygen and water are produced at the anode. In order to respond to fluctuations in the output of replay energy, research into electrolyte membranes (membrane water electrolysis) is being actively conducted.
・Alkaline water electrolysis performance evaluation device
Fossil fuel reforming (partial oxidation/ water vapor)
Partial reforming: Hydrocarbon fuel is reacted with water vapor at high temperatures (800°C) to produce hydrogen. Carbon dioxide is also produced as a by-product. water vapor reforming: Fuel is first mixed with air and then burned to produce a mixture of hydrogen and carbon monoxide.
・Reformed fuel SOFC evaluation device
Catalyst evaluation equipment
carry
Organic Hydride
Hydrogen is reacted with toluene to produce methylcyclohexane (MCH), which is then transported and stored, and hydrogen is extracted and used through a dehydrogenation reaction at the point of demand. The toluene remaining after dehydrogenation is returned to the MCH manufacturing plant.
・MCH electrolysis test evaluation device
Save
High pressure hydrogen (hydrogen station/hydrogen pump)
Hydrogen stations are spreading all over the country. In order to transport hydrogen efficiently, it needs to be compressed. Electrochemical hydrogen pumps can compress hydrogen using replay energy.
・Performance evaluation device for electrochemical hydrogen pumps for pressurization
・Solid polymer membrane evaluation device
use
Stationary fuel cells (home and industrial SOFC)
Hydrogen extracted from city gas or LP gas, or hydrogen obtained by electrolyzing replay energy, is subjected to a chemical reaction with oxygen in the air to generate the electricity and heat needed for daily life.
・Home fuel cell system (ENE-FARM) shipment inspection device
Fuel cell vehicle (FCV)
This is an electric vehicle that generates electrical energy from hydrogen and oxygen using fuel cells installed in the vehicle body, and uses the energy to power the motor.
・100kW class PEFC stack evaluation device
- Thermostatic chamber for evaluating PEFC stacks
・In-vehicle hydrogen pump environmental performance evaluation device
Catalyst evaluation equipment

Advantages of Chino fuel cell evaluation equipment

Long-control know-how

high accuracy humidification gas dew point control
Dew point range: -40℃ to 150℃
Dew point stability: ±1℃ (dew point 10℃~150℃)
fc_sp1
Unique control method for stack cooling water volume and temperature (Patent registration number 5107548)
Eliminates the effects of unstable pump discharge flow and exhaust heat, achieving advanced flow and temperature control.
SOFC evaluation holder

The all-ceramic design is not affected by metal poisoning and releases thermal stress. It can be used for evaluations under high fuel utilization rates and space-saving tests.
fc_sp2a

fc_sp2b
Equipment Safety

  • Fail-safe design
H2 gas leak prevention
In addition to being equipped with an H2 gas detector, the device is designed so that gas does not accumulate (the top lid is not sealed) in the unlikely event of an accident.
fc_sp3
Dry cooking monitoring
Dry-running is detected and prevented based on a combination of data such as tank water level and heater abnormalities.
  • Duplicate alarm (redundant design)
  • Various interlocks
Malfunction /deterioration diagnosis

  • Determine and monitor equipment deterioration over time based on measurement data and operating status data*
  • Support for building big data for deterioration diagnosis (using AI)
*Example of operation status data
  • Mass flow controller flow rate deviation
  • current and voltage of heaters and electronic load
  • Solenoid valve opening and closing times
  • Airtightness of the device, etc.
fc_sp4
Construction of remote monitoring and control system

fc_sp5

Product introduction

Evaluation Test Equipment

SOFC evaluation test equipment
fc_sp3
  • For performance testing of button type cells
  • Compact configuration
  • Easy-to-use operation
  • Compatible with reformed simulated gas
  • Gas humidification dew point: 10 to 90°C
PEFC evaluation test equipment
fc_sp3
  • For performance and durability testing of single cells
  • Gas temperature control near the cell
  • control possible from low dew point
  • Easy to build. Easy to use and enables automated operation.
Water electrolysis evaluation equipment
fc_sp3
  • For performance and durability testing of electrolytic cells
  • Supports hydrogen generation pressure up to 1MPa
  • Equipped with a safety function that detects abnormalities and stops operation

SOFC evaluation holder

Large cell holder
fc_sp3
  • Supports 50 and 100 mm sizes (square)
  • Ceramic construction means no metal contamination of the cell
  • High temperature spring structure designed to relieve thermal stress
Small SOFC holder
fc_sp3
  • Compact and space-saving design
  • Easy cell installation and replacement
  • Ceramic construction means no metal contamination of the cell

Sensors

Intrinsically safe explosion proof
Platinum-cobalt sheathed resistance thermometer
fc_sp3
  • Capable of precise measurement from 4K to room temperature
  • explosion proof class and ignition level of target gas or steam: ⅡCT4Ga
  • For measuring temperature during the production, transportation, storage and use of liquid hydrogen

Humidification, software, data acquisition equipment

High flow rate humidification
fc_sp3
  • Supports full stack gas flow
  • Dew point stability: within ±2.0℃
  • Compact size (less than half the capacity of our previous products)
PEFC evaluation test equipment
fc_sp3
  • Specialized interface for test monitors
  • Large capacity and high-speed speed data processing
  • Windows 10 Support

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.