Thermal Conductivity Hygrometer/Saturation Meter MH6

The MH6 series is a ventilation type hygrometer/saturation differential meter that uses a new principle, development thermal conduction humidity sensor. Thermal conduction humidity sensors do not dew condensation when energization on, and are not easily affected by chemicals. Even in high humidity environments, the measured value does not saturate, and accurate measurement is possible with a high-speed response. There is also a model that can directly measure the humidity parameter "saturation differential," which is important for crop cultivation environments.

Thermal conductivity hygrometer/saturation meter for use in test rooms prone to high humidity and in environments where animals and plants are raised

  • Equipped with a new thermal conductivity humidity sensor. The sensor is heated to several hundred degrees Celsius, so dew condensation does not occur.
  • Fast response even in high humidity environments
  • The sensor unit is a fully interchangeable type, so only the sensor unit can be replaced, making maintenance easy.
  • The product body is equipped with a ventilation fan. It forcibly takes in the air around the product to measure temperature/humidity
  • Capable of measuring saturation deficit, which can be used for plant growth
  • Models with temperature output of Pt100 (3-wire resistance thermometer output) are also available.

Application Examples

  • Plant Factory
  • Mushroom cultivation facility
  • Temperature and humidity chamber
  • Animal Breeding Room

Specifications

Model list

Product name Specifications Models
Main unit Thermal Conduction Hygrometer Humidity/Temperature 4-20mA output MH6A10
Humidity 4-20mA, Temperature Pt3 wire MH6B10
Thermal Conduction Saturation Gauge Saturation deficit/temperature 4 to 20mA output MH6A20
Saturation deficit 4 to 20mA, temperature Pt3 wire MH6B20

General specifications

Models MH6A10 MH6A20 MH6B10 MH6B20
Humidity Sensors Heat conduction type
output Relative humidity Satirability Relative humidity Satirability
Measurement range 0~100%rh 0-48g/ m3 0~100%rh 0-48g/ m3
Output Signal 4 to 20mA DC (within the measurement range)
load resistance 500 Ω or less
temperature Sensors Thermistor Platinum resistance thermometer Pt100
Measurement range 0~60℃
Output Signal 4 to 20mA DC (for 0 to 60°C) Pt100Ω・3-wire system
load resistance 500 Ω or less
Sensor compatibility Compatibility
Operating temperature limit 0~60℃
Power supply voltage 24V DC±10%
mass Approx. 1.3kg

Download Documents & Softwares

Catalog

Specification Sheet (PS Sheet)

CAD Data

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • MH6
    ファイルサイズ1MB
    Downloads
  • MH6
    ファイルサイズ1MB
    Downloads

Instruction Manual

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • Thermal Conduction Thermo-temperature/humidity /Saturation Difference Meter MH6 Series
    ファイルサイズ3MB
    Models
    MH6
    Document No.
    MH6-00
    Downloads
  • Replacement fan unit for MH6 series MH6F00
    ファイルサイズ1MB
    Models
    MH6
    Document No.
    MH6F-00
    Downloads
  • Replacement sensor unit for MH6 series MH6S00
    ファイルサイズ1MB
    Models
    MH6
    Document No.
    MH6S-00
    Downloads

Softwares

Application Examples

RelatedInfo

movie

FAQ

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.