The MA series CO2 monitors are wall-mounted CO2 (carbon dioxide) concentration meters that use a solid electrolyte or infrared absorption sensor detection method and are equipped with functions such as a digital display of measured values and an analog output signal. They are available with an alarm specifications that outputs a warning value mechanical relay output or sounds a buzzer, and with a control function that is equipped with a relay output for adjusting the CO2 concentration. There is also an aspirating type that can measure the CO2 concentration by aspirating gas from places where a CO2 monitor cannot be directly installed.
Model | Type | Measurement range | Models |
---|---|---|---|
With alarm function | Wall Mounting Type (Solid electrolyte type) |
100-5,000 ppm | MA100□-00 |
0.01~10.00% | MA100□-10 | ||
Wall Mounting Type (Infrared absorption method) |
0-5000 ppm | MA110□-00 | |
Wall-mounted suction type (Solid electrolyte type) |
100-5,000 ppm | MA100□-0P | |
0.01~10.00% | MA100□-1P | ||
With control function | Wall Mounting Type (Solid electrolyte type) |
100-5,000 ppm | MA500□-00 |
0.01~10.00% | MA500□-10 | ||
Wall Mounting Type (Infrared absorption method) |
0-5000 ppm | MA510□-00 | |
Wall-mounted suction type (Solid electrolyte type) |
100-5,000 ppm | MA500□-0P | |
0.01~10.00% | MA500□-1P |
Measurement principle | Lithium-ion solid electrolyte system | Infrared absorption method |
---|---|---|
Measurement range | 100~5000ppm, 0.01~10.00% | 0-5000 ppm |
Measurement value display | 4-digit digital display with red LED | |
Resolution | 5000ppm range 10ppm (less than 3000ppm)/25ppm (more than 3000ppm) 10% range 0.01–0.99% (0.01%) 1.0–10.0% (0.1%) |
10ppm (less than 3000ppm)/25ppm (more than 3000ppm) |
Accuracy ratings | 5000ppm range ±7% of measured value ±10ppm (less than 3000ppm) ±7% of measured value ±25ppm (3000ppm or more) 10% range ±10% ±0.01% (0.01 to 0.99%) of measured value ±10% ±0.1% of measured value (1.0 to 10.0%) |
(±50 ppm or 5% of measured value) ±10 ppm (±50 ppm or 5% of measured value) ±25 ppm |
Response time | Within 120 seconds (90% response) | Within 180 seconds (90% response) |
Alarm Output | higher limit and lower limit individual LED lamps lights higher limit / lower limit mechanical relay output (only with alarm function) |
|
control Output | control LED lamp for signal output lights 1 circuit a contact mechanical relay output (with control function only) |
|
transmission signal output | 4 to 20mADC or 1 to 5VDC (For 0-5000ppm, 0.0-10.0%) |
|
Warm-up time | Approximately 30 minutes | 約60秒 |
Calibration | One-point calibration of inspection gas using a special inspection kit | |
Power supply | 100VAC±10%, 50/60Hz | 24V DC |
Power consumption | 約8VA | Maximum 4W |
Operating temperature limit | 0~45℃ | 0~50℃ |
Operating humidity range | 95% RH or less (but no dew condensation) | |
External dimensions | Wall mounting type W120×H120×D55mm Wall-mounted suction type W223×H321×D140mm |
|
Weight | Wall-mounted type Approx. 430g Wall-mounted suction type Approx. 2.3 kg |
約430g |
Office air conditioning, dry ice detection, CO2 refrigerant leak detection boiler, plant factory, mushroom cultivation
If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.