The SE3000 is an input scanner that can be connected to a PC to collect data. The base unit has six input points, and up to seven subunits (for a maximum of 48 points) can be added to each unit with six input points each. These can be combined to import analog data.
We provide a package software for data processing, "data acquisition software (KIDS)," and "parameter Setting Software (PASS)," which allows you to set the input range, etc.

Enhanced compatibility with PCs Expandable up to 48 channels

  • Since it is an expansion type, the number of input points can be expanded up to 48 points by connecting a sub-unit (6 input points) as necessary.
  • Uses the international MODBUS communication protocol. Communication with MODBUS-equipped devices is possible without creating communication software.
  • Three communication interface are standard: RS-232C, RS-422A, and RS-485.
  • universal input inputs allow you to choose from 30 types such as DC voltage, thermocouples, and resistance thermometer
  • high-speed and high sensitivity measurement, multi-computation
  • The inputs are insulation between all channel for safe use.
  • Can also be used to expand the number of inputs (up to 24) for the paperless graphic recorder BR series

Other features

data acquisition software "KIDS" and parameter setting software "PASS" are available, making data acquisition easy. KIDS can connect up to 5 SE3000 units and can manage up to 100 channel.

Specifications

Model list

Name Models
Base unit Without display SE3100-000
With display SE3101-000
unit for additional input SE3211-000
Software KIDS/PASS

Specifications

Specifications

Number of measurement points 6 base unit, 6 subunits per unit
* Up to 7 unit can be connected to one base unit, allowing for expansion up to 48 points.
Input Type universal input
9 types DC voltage, 16 types of thermocouple, 5 types of resistance thermometer
* Thermocouples are only compatible with the base unit.
Accuracy ratings ±0.1%±1digit (DC voltage, general-purpose thermocouple)
Measurement Interval 1 second (for 6 points) to 8 seconds (for 48 points)
burnout Equipped as standard with a sensor disconnection detection function for thermocouple and resistance thermometer inputs (can be switched on/off)
communication interface RS-232C, RS-422A, RS-485 (select from three types with a switch)
*Communication protocol is MODBUS
constant Up to 4 settings per channel
Alarm Type higher limit, lower limit, differential high alarm, differential low alarm, rate-of-change increase limit, rate-of-change decrease limit (no alarm output)
External dimensions Base unit H136 x W72 x D100mm
unit H136×W36×D100mm
Installation Method DIN (35mm) rail mounting
Rated power supply voltage 100V-240VAC 50/60Hz

display specifications (option, can be retrofitted)

display 7 segment red LED 7 digits
display Content 2-digit channel number, 5-digit data (channel increment/fixed)
display update cycle 3秒

Download Documents & Softwares

Catalog

Specification Sheet (PS Sheet)

  • English) SE3000 増設形スキャナ
    ファイルサイズ1MB
    Document No.
    PSE-300
  • SE3000 add-on scanner
    ファイルサイズ4MB
    Document No.
    PS-81-6

CAD Data

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • SE3000 (base unit)
    ファイルサイズ1MB
    Downloads
  • SE3000 (sub unit)
    ファイルサイズ1MB
    Downloads

Instruction Manual

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • End of sales of Ethernet communication interface for AL3000/AH3000/BR1000/SE3000
    ファイルサイズ1MB
    Models
    SE3000
    Document No.
    SE3-14-5
    Downloads
  • Add-on scanner SE3000
    ファイルサイズ1MB
    Models
    SE3000
    Document No.
    SE3-12-8
    Downloads
  • Expansion scanner [Communication] SE3000
    ファイルサイズ1MB
    Models
    SE3000
    Document No.
    SE3-11-5
    Downloads
  • English)SE3000 Field Scanner [Communications Interfaces]
    ファイルサイズ1MB
    Models
    SE3000
    Document No.
    INE-301B
    Downloads
  • SE3000 Field Scanner
    ファイルサイズ1MB
    Models
    SE3000
    Document No.
    INE-300E
    Downloads

Softwares

Application Examples

RelatedInfo

movie

FAQ

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.