The KE series is a network-compatible logger suitable for high-speed, multi points data acquisition. Each function is unit, and you can build a system that meets your needs by combining the necessary unit.
Ethernet or USB is available for primary communication, and the USB is equipped with RS-422A and RS-485 with MODBUS protocol for secondary communication.

The most advanced data acquisition technology, pursuing high-speed speed, simultaneity, and expandability

  • Collects up to 300 channel of data in 0.1 seconds (USB model)
  • Records 60 channel of data to a memory card in 0.05 seconds (Ethernet model)
  • Alarm computation for 60 channel execution every 0.05 seconds
  • multi points measurement of up to 1860 channel using serial communication (RS-422A/RS-485)
  • Improved maintainability

Other features

Dedicated simple application software is included as standard (USB model).

Specifications

Models

Model Models
Input unit analog Input KE331L-000
Communication unit Ethernet KE3200-E00
USB KE3200-U00
Power supply unit Without display KE3100-000
With display KE3101-000

Specifications

Input specifications

Number of measurement channel 60 channel /set, 12 channel channel unit unit structure expanding from 12 to 60 channel
Input Type universal input
DC voltage ±10mV, ±20mV, ±40mV, ±80mV
±1.25V, ±2.5V, ±5V, ±10V
DC current Supported by adding an external shunt resistor
(Sold separately)
thermocouple B, S, R, N, K, E, J, T,
WRe5-WRe-26, W-WRe26,
PlatinelⅡ, PtRh40-PtRh20, U, L
resistance thermometer
(Measurement current 400μA)
Pt100, JPt100
Digital input (relay, open collector)
Accuracy ratings ±0.1% of measurement range ±1 digit (K thermocouple)
temperature drift ±0.01%FS/℃
Measurement Interval Approx. 18 ms/ channel (approx. 18 ms/60 channel)
reference junction compensation accuracy K, E, J, T, N, PlatinelⅡ ±0.5℃ or less
S, R, WRe5-WRe26, W-WRe26, U, L ±1℃ or less
However, B and PtRh40-PtRh20 are excluded.
(If the reference point compensation is internal, add the above error to the accuracy.)
burnout Detects disconnection of input signal for thermocouple input and resistance thermometer input.
Judgment on/off can be selected for each input

General specifications

Rated power supply voltage 100-240V AC 50/60Hz
power consumption Maximum 60VA (for 60 channel
Normal operating conditions Ambient temperature/humidity range 0 to 50℃ 20 to 80% RH
Power supply voltage 90 to 264V AC
Power frequency 50/60Hz ±2%
posture Within 3° forward and backward
Power outage countermeasures EEPROM stores settings and calibration data
Installation Method 35mm wide DIN rail mounting (vertical mounting)
mass Power supply unit: approx. 600g
Communication unit: approx. 300g
Input unit: approx. 700g

Download Documents & Softwares

Catalog

Specification Sheet (PS Sheet)

  • KE Series Network Logger
    ファイルサイズ2MB
    Document No.
    PS-86-5

CAD Data

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • KE (USB unit)
    ファイルサイズ1MB
    Downloads
  • KE (Ethernet)
    ファイルサイズ1MB
    Downloads
  • KE (power supply unit)
    ファイルサイズ1MB
    Downloads
  • KE (input unit)
    ファイルサイズ1MB
    Downloads

Instruction Manual

*Downloading materials is a members-only service.
*If you wish to download, please login as a member and click "Download."
  • Network Logger KE3000 General
    ファイルサイズ2MB
    Models
    K.E.
    Document No.
    KE3-11-7
    Downloads
  • ネットワークロガー KE3000 イーサネット通信ユニット Web・メモリ機能
    ファイルサイズ9MB
    Models
    K.E.
    Document No.
    KE3-13-6
    Downloads
  • Network logger KE3000 installation and connections
    ファイルサイズ1MB
    Models
    K.E.
    Document No.
    KE3-12-6
    Downloads

Softwares

Application Examples

RelatedInfo

movie

FAQ

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.

You must be a login to download.