specifications separate temperature/humidity /pressure-resistant and heat-resistant HN-CJ is temperature/humidity that can withstand a pressure of 1 MPa and a heat temperature of 180°C. It can measure temperature/humidity in heated and high-temperature atmospheres, and has ensured durability in H2 atmospheres at high temperatures exceeding 100°C.
It is possible to measure relative humidity even at dew point temperatures of 100°C or higher, and it can be used for various temperature/humidity measurement and management purposes, such as humidification control and humidification monitors for fuel cell performance evaluation tests, and constant temperature and humidity chambers.
Cable length | Output signal (4 to 20mA DC, 2-wire transmission) | |
---|---|---|
Temperature, relative humidity | Temperature, dew point temperature | |
1m | HN-CJA1 | HN-CJC1 |
2m | HN-CJA2 | HN-CJC2 |
3m | HN-CJA3 | HN-CJC3 |
Models | HN-CJA | HN-CJC | |
---|---|---|---|
Output Signal | Temperature, relative humidity | Temperature, dew point temperature | |
Humidity | Sensors | Polymer Capacitive Type | |
Measurement range | 0 to 100%rh (but do not allow dew condensation, maximum dew point temperature 150℃) | ||
Accuracy ratings | ±2%rh (0 to 90%rh, at 25°C) | ||
Response time | Less than 30 seconds (90% response) | ||
temperature | Sensors | Platinum resistance thermometer | |
Measurement range | -40~180℃ | ||
Accuracy ratings | ±0.5°C (at 25°C) | ||
Output Signal | 4 to 20mA DC 2-wire transmission (2 systems) | ||
For temperatures between -40 and 180°C and relative humidity between 0 and 100%rh | For temperatures between -40 and 180°C, dew point temperatures between -40 and 180°C | ||
Dew point temperature computation from relative humidity and temperature measurements | |||
Sensor compatibility | Plug-in compatible, including cable | ||
Operating temperature limit | Main unit | 0~50℃ | |
Sensor Unit | -40~180℃ | ||
Power supply voltage | 12-24V DC | ||
Weight (main unit only) | 約220g |
*HN-CJA can be used in combination with the humidity computation HN-GVAF1□ to convert humidity unit
(Absolute humidity g/m 3, water vapor pressure kPa, relative humidity %rh, dew point temperature ℃, mixing ratio g/kg, comparative humidity (%)) are possible
If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.