Achieving a high emissivity of 0.995 or more, ideal for scale radiation thermometer! New release of high emissivity flat blackbody furnace.

2023.03.29
News Release
Measurement, control ・Monitoring and Systems CHINO Corporation (headquartered in Itabashi-ku, Tokyo; Mikio Toyoda, President) released a high emissivity plane blackbody furnace, IR-R40, on Wednesday, March 29.

Chino, in collaboration with the National Institute of Advanced Industrial Science and Technology (AIST), a national research development corporation, has development developed a flat blackbody device that serves as a precise (precise and accurate) reference for measuring temperature for thermal cameras and radiation thermometer used for non-contact temperature inspection and other applications. (Press release on January 19, 2022)

The high emissivity flat blackbody furnace "IR-R40" is a flat blackbody device that uses high emissivity blackbody material with emissivity as close to 1 as possible. In conventional flat blackbody devices, the emissivity of the blackbody material used is as low as 0.96 to 0.98, so this low value is an error factor for the radiation temperature standard, and the background infrared radiation reflected from the blackbody surface affects the temperature measurement. However, AIST has devised development a black resin surface structure, and this blackbody has an extremely high emissivity and reflects almost no background infrared rays, thus realizing an almost ideal radiation temperature standard.

In recent years, thermal imaging cameras and radiation thermometer are being used for screening in commercial facilities, but in order to get an accurate temperature, a "calibration" is required to check the difference between the temperature reference value and the display of the thermometer being used. By using the flat blackbody furnace as a reference, the reliability of the measured temperature can be improved.

The small size and light weight of the thermometer make it easy to carry and install, allowing for easy calibration of the thermometer in the field. We will promote sales of this product so that it can be used for accurate temperature measurement in large commercial facilities, hospitals, airports/railways, schools, government offices, factories, etc.

Features

  • High emissivity ε = 0.995 or higher
  • Compact, lightweight, and easy operation
  • Can be installed on a table or on a tripod
  • With communication interface

General specifications

Calibration Temperature Range (Ambient temperature +5)℃ to 50℃
Radiation surface size 60mm x 60mm
Temperature stability *1 ±0.15℃/30min
Temperature distribution *2 ±0.15℃ (when set to 37℃)
Indication accuracy※3 ±0.2℃ (when set to 37℃)
emissivity *4 0.995 or higher
communication interface RS-485
Rated power supply voltage 100VAC (50/60Hz)
Maximum power consumption 60VA
Ambient temperature 0℃~40℃
Mass 約2.1kg
*1: May vary depending on the surrounding environment.
*2: Radiation surface size: 48mm square, ambient temperature: 23℃±5℃
*3: Ambient temperature 23℃±5℃
*4: Average spectral emissivity of 6μm to 14μm

exterior

IR-R40 appearance IR-R40 Parts Names

If you have any problems with temperature control,
 please feel free to contact us.

Membership
CHINO Web Membership Information

If you register as a CHINO Web member, you will be able to view the product's instruction manual.
If you wish, we will send you the latest information on CHINO products via email.